Published September 2001 | Version v1
Book

Nuclear safety - a reliability perspective

  • 1. Indira Gandhi Centre for Atomic Research, Kalpakkam (India)

Description

This paper examines the role of the k/N systems in improving the reliability of the radiation monitoring systems with β factor Common Cause Factor (CCF) model

Part of:
Nuclear technology - challenges in the 21st century. V.1: contributed papers

Additional details

Publishing Information

Publisher
Indian Nuclear Society
Imprint Place
Mumbai (India)
Imprint Title
Nuclear technology - challenges in the 21st century. V.1: contributed papers
Imprint Pagination
362 p.
Journal Page Range
p. 160-164

Conference

Title
12. annual conference of Indian Nuclear Society
Acronym
INSAC-2001
Dates
10-12 Oct 2001
Place
Indore (India)

INIS

Country of Publication
India
Country of Input or Organization
India
INIS RN
33003983
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
FAILURES; GAMMA DETECTION; GAMMA DOSIMETRY; NUCLEAR INDUSTRY; PROBABILITY; RADIATION MONITORING; RADIATION PROTECTION; REACTOR SAFETY; RELIABILITY
Descriptors DEC
DETECTION; DOSIMETRY; INDUSTRY; MONITORING; RADIATION DETECTION; SAFETY

Optional Information

Notes
5 refs., 1 fig., 1 tab.