Evaluating childhood obesity. Magnetic resonance-based quantification of abdominal adipose tissue and liver fat in children
Creators
- 1. Leipzig Univ. Medical Center (Germany). IFB Adiposity Diseases
- 2. Leipzig Univ. (Germany). Dept. of Paediatric Radiology
- 3. Leipzig Univ. (Germany). Clinical Trial Centre Leipzig
- 4. Leipzig Univ. (Germany). University Hospital for Children and Adolescents
- 5. Leipzig Univ. (Germany). Dept. of Oral, Craniomaxillofacial and Facial Plastic Surgery
- 6. Univ. Hospital Tuebingen (Germany). Section on Experimental Radiology
Description
The purpose of this study is to establish and validate a magnetic resonance (MR)-based fat quantification package that provides an accurate assessment of abdominal adipose tissue and liver fat in children. Ex vivo trials with a torso model and water-oil mixtures are conducted. Abdominal adipose tissue (AAT) is covered by magnetic resonance imaging (MRI) using a fat-selective sequence and is analyzed by a plug-in based on the open source software Image. Liver fat (LF) is measured with localized 1H Magnetic Resonance Spectroscopy (1H MRS) and the jMRUI (java-based Magnetic Resonance User Interface) software package. Evaluation of the clinical methodology involved a study of 10 children in this feasibility study (mean age and body mass index: 13.3 yr; 33.3 kg/m2). To evaluate the method's validity, reference measurements were performed. Ex vivo trials with the torso model showed that adipose tissue was measured appropriately with a systematic underestimation by 9.3 ± 0.2 % (0.32 ± 0.064 kg). Coefficients of variation for both intra- and inter-observer measurements ranged between 0 - 2.7 % and repeated analyses showed significant equivalent results (p < 0.01). The lipid content obtained by 1H MRS ex vivo revealed significant equivalence with the predefined fat content in water-oil mixtures (p < 0.01). In vivo, the homemade plug-in significantly overestimated the AAT, with the visceral adipose tissue being most affected (+ 15.7 ± 8.4 %). Although an overestimation of the AAT by the presented plug-in should be taken into consideration, this children-friendly package enables the quantification of both LF and AAT within 30 min on a freeware-based platform. (orig.)
Additional details
Publishing Information
- Journal Title
- RoeFo - Fortschritte auf dem Gebiete der Roentgenstrahlen und der bildgebenden Verfahren
- Journal Volume
- 184
- Journal Issue
- 4
- Journal Page Range
- p. 324-332
- ISSN
- 1438-9029
- CODEN
- RFGNDO
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 43071078
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ABDOMEN; ADIPOSE TISSUE; CHILDREN; FAT CELLS; FEASIBILITY STUDIES; HYDROGEN 1; LIVER; METABOLIC DISEASES; NMR IMAGING; NMR SPECTRA; PEDIATRICS; PHANTOMS; RELIABILITY; VALIDATION
- Descriptors DEC
- AGE GROUPS; ANIMAL CELLS; ANIMAL TISSUES; ANIMALS; BODY; CONNECTIVE TISSUE; CONNECTIVE TISSUE CELLS; DIAGNOSTIC TECHNIQUES; DIGESTIVE SYSTEM; DISEASES; GLANDS; HYDROGEN ISOTOPES; ISOTOPES; LIGHT NUCLEI; MAMMALS; MAN; MEDICINE; MOCKUP; NUCLEI; ODD-EVEN NUCLEI; ORGANS; PRIMATES; SOMATIC CELLS; SPECTRA; STABLE ISOTOPES; STRUCTURAL MODELS; TESTING; VERTEBRATES