Assessment of accuracy and efficiency of atlas-based autosegmentation for prostate radiotherapy in a variety of clinical conditions
- 1. Medical Univ. Vienna/AKH Vienna (Austria). Div. of Medical Radiation Physics
- 2. Medical Univ. Vienna (Austria). Christian Doppler Lab. for Medical Radiation Research for Radiation Oncology
- 3. Medical Univ. Vienna (Austria). Center for Medical Physics and Biomedical Engineering
Description
Background and purpose: The goal of the current study was to evaluate the commercially available atlas-based autosegmentation software for clinical use in prostate radiotherapy. The accuracy was benchmarked against interobserver variability. Material and methods: A total of 20 planning computed tomographs (CTs) and 10 cone-beam CTs (CBCTs) were selected for prostate, rectum, and bladder delineation. The images varied regarding to individual (age, body mass index) and setup parameters (contrast agent, rectal balloon, implanted markers). Automatically created contours with ABAS registered and iPlan registered were compared to an expert's delineation by calculating the Dice similarity coefficient (DSC) and conformity index. Results: Demo-atlases of both systems showed different results for bladder (DSCABAS 0.86 ± 0.17, DSCiPlan 0.51 ± 0.30) and prostate (DSCABAS 0.71 ± 0.14, DSCiPlan 0.57 ± 0.19). Rectum delineation (DSCABAS 0.78 ± 0.11, DSCiPlan 0.84 ± 0.08) demonstrated differences between the systems but better correlation of the automatically drawn volumes. ABAS registered was closest to the interobserver benchmark. Autosegmentation with iPlan registered, ABAS registered and manual segmentation took 0.5, 4 and 15-20 min, respectively. Automatic contouring on CBCT showed high dependence on image quality (DSC bladder 0.54, rectum 0.42, prostate 0.34). Conclusion: For clinical routine, efforts are still necessary to either redesign algorithms implemented in autosegmentation or to optimize image quality for CBCT to guarantee required accuracy and time savings for adaptive radiotherapy. (orig.)
Additional details
Publishing Information
- Journal Title
- Strahlentherapie und Onkologie
- Journal Volume
- 188
- Journal Issue
- 9
- Journal Page Range
- p. 807-813
- ISSN
- 0179-7158
- CODEN
- STONE4
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 43107494
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ACCURACY; ALGORITHMS; BENCHMARKS; BIOLOGICAL LOCALIZATION; BLADDER; CARCINOMAS; COMPUTERIZED TOMOGRAPHY; ERRORS; NEOPLASMS; PROSTATE; RADIOTHERAPY; RECTUM; SAFETY MARGINS
- Descriptors DEC
- BODY; DIAGNOSTIC TECHNIQUES; DIGESTIVE SYSTEM; DISEASES; GASTROINTESTINAL TRACT; GLANDS; INTESTINES; LARGE INTESTINE; MALE GENITALS; MATHEMATICAL LOGIC; MEDICINE; NEOPLASMS; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; THERAPY; TOMOGRAPHY; URINARY TRACT