Published 1986 | Version v1
Journal article

Improved uranium MC and A by using good measurement QC and QA

Creators

  • 1. Savannah River Plant, E.I. du Pont de Nemours and Co., Inc., Aiken, SC 29808

Description

In a purification process at the Savannah River Plant (SRP), a long-term gain trend existed in the accountability of enriched uranium. A major effort was made to improve uranium assays for input accountability. The isotope dilution-mass spectrometry method in use was converted from a volumetric basis to a gravimetric basis. Analysts were formally qualified for performing routine measurements by successfully completing tests on blind standards. Tight quality-control limits were established. The performance of analysts was closely monitored, and it became necessary to limit measurements to several analysts in order to achieve a sustained high level of performance. Quality control standards were monitored and improvements made to ensure valid standards. Standard and sample analytical results were examined for trends on a continuing basis. As improvements in uranium assays continued, it became evident that sampling was a major problem. With the implementation of a good sample validation program, improvements in uranium assays, and improvements in quality control, the uranium gain trend was eliminated

Additional details

Publishing Information

Journal Title
Nucl. Mater. Manage.
Journal Volume
15
Series
Nucl. Mater. Manage.
Journal Page Range
203-207
ISSN
0362-0034
CODEN
NUMMB

Conference

Title
27. annual meeting of the Institute of Nuclear Materials Management.
Dates
22-25 Jun 1986.
Place
New Orleans, LA (USA).

Optional Information

Secondary number(s)
CONF-860654--.