Doses optimization to patients in computed tomography studies
Creators
- 1. Hospital Regional de Alta Especialidad de Oaxaca, Aldama s/n, Paraje El Tule, 71256 San Bartolo Coyotepec, Oaxaca (Mexico)
Description
in recent years the number of studies of computed tomography has been increased, as well as the technology and methodology of these, while the radiological protection to the patient has not advanced to the same step. The IAEA has implemented the Patients Radiation Protection projects, where one of the areas of more interest is the computed tomography. The present work is a brief summary of the actions to realize for the doses optimization imparted to the patients, obtaining an appropriate diagnostic quality in the images at the same time; as it was presented in the course of the project C-RLA/9/067-001. The results that were obtained between Image Quality and Dose by Radiation that is imparted to the patient are shown, as well s the exposition factors that influence in these, according to the project C-RLA/9/067-001. The main actions for the dose optimization are using tension optimized protocols (kV), of load (m As), of collimation/cut thickness, of inclination of the gantry, of the pitch/displacement by rotation, of the reconstruction algorithm (kernel), according to the diagnostic objective to reach and to the patient physical characteristics (like weight and age), as well as to use protections to shield the sensitive organs (mainly those that do not have clinical interest for the procedure). Conclusion: To establish or to begin to implement, insofar as possible, the IAEA recommendations, relating to the clinical practice of the hospitals in Mexico and to the available equipment s type. (Author)
Availability note (English)
Available from the Instituto Nacional de Investigaciones Nucleares, Centro de Informacion y Documentacion Nuclear, 52750 Ocoyoacac, Estado de Mexico (MX), e-mail: javier.ortega@inin.gob.mx; claudio.fernandez@inin.gob.mx;Additional details
Additional titles
- Original title (Spanish)
- Optimizacion de las dosis a pacientes en estudios de tomografia computada
Publishing Information
- Publisher
- Sociedad Mexicana de Seguridad Radiologica A. C.
- Imprint Place
- Mexico D. F. (Mexico)
- Imprint Pagination
- 10 p.
Conference
- Title
- toward a continuous improvement of the radiological protection in Mexico
- Original Conference Title
- 12. Congreso Nacional: hacia una mejora continua de la proteccion radiologica en Mexico
- Acronym
- 12. National Congress
- Dates
- 11-13 Nov 2009
- Place
- San Luis Potosi, SLP (Mexico)
INIS
- Country of Publication
- Mexico
- Country of Input or Organization
- Mexico
- INIS RN
- 42000585
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- ALGORITHMS; COMPUTERIZED TOMOGRAPHY; DOSES; HOSPITALS; IAEA; IMAGES; INCLINATION; KERNELS; MEXICO; OPTIMIZATION; PATIENTS; RADIATION PROTECTION; RECOMMENDATIONS; ROTATION; SAFETY; THICKNESS
- Descriptors DEC
- BUILDINGS; DEVELOPING COUNTRIES; DIAGNOSTIC TECHNIQUES; DIMENSIONS; INTERNATIONAL ORGANIZATIONS; LATIN AMERICA; MATHEMATICAL LOGIC; MEDICAL ESTABLISHMENTS; MOTION; NORTH AMERICA; TOMOGRAPHY
Optional Information
- Funding organization
- Instituto Nacional de Investigaciones Nucleares (Mexico); Comision Nacional de Seguridad Nuclear y Salvaguardias (Mexico); Comision Federal para la Proteccion contra Riesgos Sanitarios (Mexico); Universidad Autonoma de San Luis Potosi, Facultad de Medicina (Mexico); Oficina de Congresos y Convenciones, San Luis Potosi (Mexico); Nuclemedica (Mexico); Calidad XXI (Mexico); Centro Regional de Enfermedades Oncologicas (Mexico); Hospital Lomas de San Luis Potosi (Mexico); AccesoFarm (Mexico); Siemens Healthcare (Mexico); Oncology Services International (United States); Servicios Integrales para la Radiacion (Mexico); ADITSA (Mexico)