Analysis and test correlation of flexible and stiff piping systems
Creators
- 1. Impell Corp., Walnut Creek, CA (USA)
- 2. Electric Power Research Inst., Palo Alto, CA (USA)
Description
An in situ pipe test program was conducted to provide a basis for evaluating piping analysis methodologies and design philosophies. In this program, a 20.3-cm boiler feedwater line with two fundamentally different support systems was tested and analyzed. One system employed hanger supports and was very flexible. The second system employed strut and snubber supports and was relatively stiff. Snapback and forced vibration tests were performed on the piping systems. The test results were used to determine piping damping values and to correlate with analyses. These analyses were used to evaluate current piping analysis methodologies and their analytical models. Also, parametric studies were performed with the analytical models to evaluate the effect of different support systems on the pipe behavior for thermal and seismic loads. In addition, the seismic analysis results were compared to quantify the differences between direct time integration and response spectra analysis methods. (orig.)
Additional details
Publishing Information
- Journal Title
- Nucl. Eng. Des.
- Journal Volume
- 77
- Journal Issue
- 3
- Series
- CODEN: NEDEA.;Nucl. Eng. Des.
- Journal Page Range
- 299-319
- ISSN
- 0029-5493
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- Netherlands
- INIS RN
- 15053216
- Subject category
- S22: GENERAL STUDIES OF NUCLEAR REACTORS; S42: ENGINEERING;
- Descriptors DEI
- MECHANICAL VIBRATIONS; PERFORMANCE TESTING; PIPELINES; PIPES; REACTOR COOLING SYSTEMS; SUPPORTS
- Descriptors DEC
- COOLING SYSTEMS; MECHANICAL STRUCTURES; REACTOR COMPONENTS; TESTING