Molecular imaging: High-resolution detectors for early diagnosis and therapy monitoring of breast cancer
Creators
- Garibaldi, F.1
- Cisbani, E.1
- Colilli, S.1
- Cusanno, F.1
- Fratoni, R.1
- Giuliani, F.1
- Gricia, M.1
- Lucentini, M.1
- Fratoni, R.1
- Lo Meo, S.1
- Magliozzi, M.L.1
- Santanvenere, F.1
- Cinti, M.N.2
- Pani, R.2
- Pellegrini, R.2
- Simonetti, G.3
- Schillaci, O.3
- Del Vecchio, S.4
- Salvatore, M.4
- Majewski, S.5
- Lanza, R.C.6
- De Vincentis, G.2
- Scopinaro, F.2
- 1. Istituto Superiore di Sanita and INFN-gr. Sanita-Rome (Italy)
- 2. University La Sapienza, Rome (Italy)
- 3. University Tor Vergata, Rome (Italy)
- 4. CNR Napoli, Naples (Italy)
- 5. Jefferson Lab, Newport News, VA (United States)
- 6. Massachusetts Institute of Technology, Cambridge, MA (United States)
Description
Dedicated high-resolution detectors are required for detection of small cancerous breast tumours by molecular imaging with radionuclides. Absorptive collimation is normally applied in imaging single photon emitters, but it results in a strong reduction in detection efficiency. Systems based on electronic collimation are complex and expensive. For these reasons simulations and measurements have been performed to design optimised dedicated high-resolution mini gamma camera. Critical parameters are contrast and signal-to-noise ratio (SNR). Intrinsic performance (spatial resolution, pixel identification, and response linearity and uniformity) were first optimised. Pixellated scintillator arrays (NaI(Tl)) of different pixel size were coupled to arrays of PSPMTs with different anode pad dimensions (6x6 mm2 and 3x3 mm2). Detectors having a field of view (FOV) of 100x100 mm2 and 150x200 mm2 were designed and built. The electronic system allows read out of all the anode pad signals. The collimation technique was then considered and limits of coded aperture option were studied. Preliminary results are presented
Additional details
Identifiers
- DOI
- 10.1016/j.nima.2006.08.098;
- PII
- S0168-9002(06)01454-9;
Publishing Information
- Journal Title
- Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
- Journal Volume
- 569
- Journal Issue
- 2
- Journal Page Range
- p. 286-290
- ISSN
- 0168-9002
- CODEN
- NIMAER
Conference
- Title
- From basic research to clinical application
- Acronym
- 3. international conference on imaging technologies in biomedical sciences innovation in nuclear and radiological imaging
- Dates
- 25-29 Sep 2005
- Place
- Milos Island (Greece)
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 38038167
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ANODES; APERTURES; DESIGN; DETECTION; DIAGNOSIS; EFFICIENCY; GAMMA CAMERAS; MAMMARY GLANDS; MONITORING; NAI DETECTORS; NEOPLASMS; PERFORMANCE; RADIOISOTOPES; READOUT SYSTEMS; SIGNAL-TO-NOISE RATIO; SIGNALS; SIMULATION; SPATIAL RESOLUTION; THERAPY
- Descriptors DEC
- BODY; CAMERAS; DIMENSIONLESS NUMBERS; DISEASES; ELECTRODES; GLANDS; ISOTOPES; MEASURING INSTRUMENTS; MEDICINE; OPENINGS; ORGANS; RADIATION DETECTORS; RESOLUTION; SCINTILLATION COUNTERS; SOLID SCINTILLATION DETECTORS
Optional Information
- Copyright
- Copyright (c) 2006 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.