MRI in multiple sclerosis: an intra-individual, randomized and multicentric comparison of gadobutrol with gadoterate meglumine at 3 T
Creators
- 1. University of Erlangen-Nuremberg, Department of Neuroradiology, Erlangen (Germany)
- 2. University Medicine Greifswald, Institute for Diagnostic Radiology and Neuroradiology, Greifswald (Germany)
- 3. SCO:SSiS, Statistical Consulting, Berlin (Germany)
- 4. University of Kiel, Department of Radiology and Neuroradiology, Kiel (Germany)
Description
To compare contrast effects of gadobutrol with gadoterate meglumine for brain MRI in multiple sclerosis (MS) in a multicentre, randomized, prospective, intraindividual study at 3 T. Institutional review board approval was obtained. Patients with known or suspected active MS lesions were included. Two identical MRIs were performed using randomized contrast agent order. Four post-contrast T1 sequences were acquired (start time points 0, 3, 6 and 9 min). If no enhancing lesion was present in first MRI, second MRI was cancelled. Quantitative (number and signal intensity of enhancing lesions) and qualitative parameters (time points of first and all lesions enhancing; subjective preference regarding contrast enhancement and lesion delineation; global preference) were evaluated blinded. Seventy-four patients (male, 26; mean age, 35 years) were enrolled in three centres. In 45 patients enhancing lesions were found. Number of enhancing lesions increased over time for both contrast agents without significant difference (median 2 for both). Lesions signal intensity was significantly higher for gadobutrol (p < 0.05 at time points 3, 6 and 9 min). Subjective preference rating showed non-significant tendency in favour of gadobutrol. Both gadobutrol and gadoterate meglumine can be used for imaging of acute inflammatory MS lesions. However, gadobutrol generates higher lesion SI. (orig.)
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00330-015-3889-7Additional details
Identifiers
Publishing Information
- Journal Title
- European Radiology
- Journal Volume
- 26
- Journal Issue
- 3
- Journal Page Range
- p. 820-828
- ISSN
- 0938-7994
- CODEN
- EURAE3
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 47053629
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BRAIN; COMPARATIVE EVALUATIONS; CONCENTRATION RATIO; CONTRAST MEDIA; GADOLINIUM COMPOUNDS; IMAGE PROCESSING; INFLAMMATION; NERVOUS SYSTEM DISEASES; NMR IMAGING; RELAXATION TIME; SIGNAL-TO-NOISE RATIO; TIME DEPENDENCE; WEIGHTING FUNCTIONS
- Descriptors DEC
- BODY; CENTRAL NERVOUS SYSTEM; DIAGNOSTIC TECHNIQUES; DIMENSIONLESS NUMBERS; DISEASES; EVALUATION; FUNCTIONS; NERVOUS SYSTEM; ORGANS; PATHOLOGICAL CHANGES; PROCESSING; RARE EARTH COMPOUNDS; SYMPTOMS