Surfactant media for constant-current coulometry. Application for the determination of antioxidants in pharmaceuticals
- 1. Analytical Chemistry Department, A.M. Butlerov Institute of Chemistry, Kazan (Volga Region) Federal University, Kremlyevskaya, 18, Kazan 420008 (Russian Federation)
Description
Highlights: ► Applicability of surfactants in constant-current coulometry is shown for the first time. ► Reactions of antioxidants with electrogenerated titrants in surfactant media are investigated. ► Water insoluble antioxidants can be determined in water media with addition of surfactants. ► Coulometric determination of antioxidants in pharmaceutical dosage forms using surfactants media is developed. - Abstract: Effect of surfactant presence on electrochemical generation of titrants has been evaluated and discussed for the first time. Cationic (1-dodecylpyridinium and cetylpyridinium bromide), anionic (sodium dodecyl sulfate) and nonionic (Triton X100 and Brij® 35) surfactants as well as nonionic high molecular weight polymer (PEG 4000) do not react with the electrogenerated bromine, iodine and hexacyanoferrate(III) ions. The electrogenerated chlorine chemically interact with Triton X100 and Brij® 35. The allowable range of surfactants concentrations providing 100% current yield has been found. Chain-breaking low molecular weight antioxidants (ascorbic acid, rutin, α-tocopherol and retinol) were determined by reaction with the electrogenerated titrants in surfactant media. Nonionic and cationic surfactants can be used for the determination of antioxidants by reaction with the electrogenerated halogens. On contrary, cationic surfactants gives significantly overstated results of antioxidants determination with electrogenerated hexacyanoferrate(III) ions. The use of surfactants in coulometry of α-tocopherol and retinol provides their solubilization and allows to perform titration in water media. Simple, express and reliable coulometric approach for determination of α-tocopherol, rutin and ascorbic acid in pharmaceuticals using surfactant media has been developed. The relative standard deviation of the measurements does not exceed of 5%.
Availability note (English)
Available from http://dx.doi.org/10.1016/j.aca.2012.07.023Additional details
Identifiers
- DOI
- 10.1016/j.aca.2012.07.023;
- PII
- S0003-2670(12)01053-7;
Publishing Information
- Journal Title
- Analytica Chimica Acta
- Journal Volume
- 744
- Journal Page Range
- p. 23-28
- ISSN
- 0003-2670
- CODEN
- ACACAM
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 44090824
- Subject category
- S37: INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY;
- Descriptors DEI
- ANTIOXIDANTS; ASCORBIC ACID; BROMINE; CHLORINE; CYANIDES; DRUGS; ELECTROCHEMISTRY; FERRATES; IODINE; MOLECULAR WEIGHT; SURFACTANTS; TITRATION; TRITONS; VITAMIN A; VITAMIN E; VOLTAMETRY; WATER
- Descriptors DEC
- CHARGED PARTICLES; CHEMICAL ANALYSIS; CHEMISTRY; ELEMENTS; HALOGENS; HYDROGEN COMPOUNDS; IRON COMPOUNDS; NONMETALS; OXYGEN COMPOUNDS; QUANTITATIVE CHEMICAL ANALYSIS; TRANSITION ELEMENT COMPOUNDS; VITAMINS; VOLUMETRIC ANALYSIS
Optional Information
- Copyright
- Copyright (c) 2012 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.