Published June 2008 | Version v1
Miscellaneous

Organ absorbed doses and effective doses to the patient and the medical staff in interventional radiology calculated from voxel phantom

  • 1. Dept. of Nuclear Engineering, Hanyang Univ., Seoul (Korea, Republic of)
  • 2. Dept. of Nuclear and Radiological Engineering, Univ. of Florida, Florida (United States)

Description

In this study, organ absorbed doses and effective doses to patient and medical staff during interventional radiological procedures were estimated using voxel phantom, Korean Typical Man-2 (KTMAN-2). Four projections of cardiac catheterization were simulated for dose calculation by Monte Carlo technique. The parameters of x-ray source and exposure conditions were obtained from literature data. Calculated doses were normalized to dose area product (DAP). The effective doses per DAP of patient were between 0.1 and 0.5 mSv Gy-1 cm-2. The results were compared with those derived from stylized phantom. KTMAN-2 received up to 105 % higher effective doses than stylized phantom. The dose differences were mainly caused by more realistic internal topology of KTMAN-2 compared to stylized phantom. For postero-anterior projection, organ absorbed dose per DAP to patient and cardiologist were calculated simultaneously. Absorbed doses per DAP of adipose tissue, lens, muscle, skin and thyroids of cardiologist were up to 0.01 mGy Gy-1 cm-2. Doses to adipose tissue, muscle and skin within hand or neck would be much higher than calculated values. The results of this study showed that voxel phantoms are more suitable for dose assessment of lying patients undergoing the interventional radiology. (author)

Part of:
Proceedings of the fourth international symposium on radiation safety and detection technology

Additional details

Publishing Information

Imprint Title
Proceedings of the fourth international symposium on radiation safety and detection technology
Imprint Pagination
765 p.
Journal Page Range
p. 309-312

Conference

Title
4. international symposium on radiation safety and detection technology
Acronym
ISORD-4
Dates
18-20 Jul 2007
Place
Seoul (Korea, Republic of)

INIS

Country of Publication
Japan
Country of Input or Organization
Japan
INIS RN
51059413
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
ADIPOSE TISSUE; EVALUATION; KOREAN ORGANIZATIONS; MEDICAL PERSONNEL; MONTE CARLO METHOD; ORGANS; PATIENTS; PHANTOMS; RADIATION DOSES; RADIATION PROTECTION; RADIOLOGY
Descriptors DEC
ANIMAL TISSUES; BODY; CALCULATION METHODS; CONNECTIVE TISSUE; DOSES; MEDICINE; MOCKUP; NATIONAL ORGANIZATIONS; NUCLEAR MEDICINE; PERSONNEL; STRUCTURAL MODELS

Optional Information

Notes
15 refs., 2 figs., 1 tab.; This record replaces 43102427 Imprint:Published as Supplement 5 (Jun 2008) of Journal of Nuclear Science and Technology. Publication month in colophon is Aug 2008