Reduced dose and improved image quality with computerized line-scan radiography system
Creators
- 1. Pittsburgh Univ., PA (United States)
- 2. Scantech Corp., Columbus, OH (USA)
Description
This paper reports on Diode-Array Digital Radiography (DADR) that reduces patient x-ray dose and improves diagnostic quality compared with conventional filmed radiography. DADR geometrically eliminates scattered x-rays by using a line-scanning technique, removing background fog. The x-ray tube is collimated to produce a fan beam of x-rays which impinges on a linear detector. The source and detector are held in alignment by a C-arm which scans the patient by translating the assembly orthogonally to the detector aperture. Each image line is exposed for a very brief time, which provides for a very short effective x-ray exposure and eliminates blurring due to patient motion. The detector uses a patented combination of scintillator, fiber optic image guides and self-scanning photodiode arrays which, in combination with scatter rejection, creates an electronic image having greater dynamic range than filmed x-rays. The image is converted to 12-bit digital computer data which may be sorted inexpensively, enhanced for diagnosis, and transferred to a PACS network. Images are displayed in full 2352 x 2000 resolution on a high-bandwidth monitor. Diagnostic experiments have concentrated on chest imaging, an application for which Scantech is developing a new product. Patient dose is typically less than half that incurred with conventional techniques
Additional details
Publishing Information
- Publisher
- IEEE Service Center.
- Imprint Place
- Piscataway, NJ (USA)
- Imprint Title
- IEEE nuclear science symposium conference record emdash 1990
- Imprint Pagination
- 1636 p.
- Journal Page Range
- p. 1102-1118.
Conference
- Title
- 1990 Institute of Electrical and Electronics Engineers (IEEE) nuclear science symposium.
- Dates
- 22-27 Oct 1990.
- Place
- Arlington, VA (USA).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 22090337
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE; S99: GENERAL AND MISCELLANEOUS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- BIOMEDICAL RADIOGRAPHY; CHEST; DIGITAL SYSTEMS; DISPLAY DEVICES; DOSE RATES; FIBER OPTICS; IMAGE INTENSIFIERS; IMAGE PROCESSING; PHOTODIODES; SCATTERING; TECHNOLOGY ASSESSMENT; X-RAY TUBES
- Descriptors DEC
- BODY; BODY AREAS; COMPUTER OUTPUT DEVICES; COMPUTER-GRAPHICS DEVICES; DIAGNOSTIC TECHNIQUES; ELECTRON TUBES; EQUIPMENT; MEDICINE; OPTICS; SEMICONDUCTOR DEVICES; SEMICONDUCTOR DIODES; X-RAY EQUIPMENT
Optional Information
- Secondary number(s)
- CONF-9010220--.