Dose rate evaluation for the shield cooling system at a CANDU nuclear power plant

  • 1. Institutul de reactori nucleari energetici, Bucharest, Romania

Description

The specific activity per isotope in the cooling light water, for the main three components of the system- pumps, heat exchangers and ion exchanger, for nine isotopes has been calculated. (authors)

Additional details

Additional titles

Original title (Romanian)
Evaluarea dozei de radiatii la sistemul de racire a protectiei biologice la o centrala nucleara de tip CANDU

Publishing Information

Imprint Title
Advances in Physics
Imprint Pagination
828 p.
Journal Page Range
p. 622-623.
Report number
INIS-mf--11440

Conference

Title
Advances in Physics.
Original Conference Title
Progrese in Fizica
Dates
6-8 Oct 1988.
Place
Constanta (Romania).

INIS

Country of Publication
Romania
Country of Input or Organization
Romania
INIS RN
20045067
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
CANDU TYPE REACTORS; RADIATION DOSES
Descriptors DEC
HEAVY WATER MODERATED REACTORS; POWER REACTORS; PRESSURE TUBE REACTORS; REACTORS; THERMAL REACTORS