Published October 2012 | Version v1
Journal article

Progress in obtaining an absolute calibration of a total deuterium–tritium neutron yield diagnostic based on copper activation

  • 1. Sandia National Laboratories, Albuquerque, New Mexico 87185 (United States)
  • 2. Chemical and Nuclear Engineering Department, University of New Mexico, Albuquerque, New Mexico 87131 (United States)

Description

The 350-keV Cockroft-Walton accelerator at Sandia National laboratory's Ion Beam facility is being used to calibrate absolutely a total DT neutron yield diagnostic based on the 63Cu(n,2n)62Cu(β+) reaction. These investigations have led to first-order uncertainties approaching 5% or better. The experiments employ the associated-particle technique. Deuterons at 175 keV impinge a 2.6 μm thick erbium tritide target producing 14.1 MeV neutrons from the T(d,n)4He reaction. The alpha particles emitted are measured at two angles relative to the beam direction and used to infer the neutron flux on a copper sample. The induced 62Cu activity is then measured and related to the neutron flux. This method is known as the F-factor technique. Description of the associated-particle method, copper sample geometries employed, and the present estimates of the uncertainties to the F-factor obtained are given.

Additional details

Identifiers

Publishing Information

Journal Title
Review of Scientific Instruments
Journal Volume
83
Journal Issue
10
Journal Page Range
p. 10D913-10D913.3
ISSN
0034-6748
CODEN
RSINAK

Optional Information

Notes
(c) 2012 American Institute of Physics