Tomography reconstruction of the intensity distribution in a beam cross-section using optical diagnostics

  • 1. ITEP, Moscow (Russian Federation)
  • 2. IPN, 91406 Orsay (France)

Description

An original experiment on tomography reconstruction of the intensity distribution in a beam cross-section was performed. It is based on an optical mapping of the beam scintillation due to interaction with the residual gas. Dedicated software realizing the algebraic reconstruction techniques was developed. In accordance with numerical simulations and experimental results, 4-8 projections are sufficient in most of the cases to reconstitute the intensity distribution in the cross-section with a good accuracy

Additional details

Identifiers

DOI
10.1016/j.nima.2007.05.205;
PII
S0168-9002(07)01014-5;

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
578
Journal Issue
1
Journal Page Range
p. 47-54
ISSN
0168-9002
CODEN
NIMAER

INIS

Country of Publication
Netherlands
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
39010396
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Descriptors DEI
ACCURACY; BEAMS; COMPUTER CODES; DISTRIBUTION; MAPPING; SCINTILLATIONS; SIMULATION; TOMOGRAPHY
Descriptors DEC
DIAGNOSTIC TECHNIQUES