Published December 2011 | Version v1
Journal article

Optimized contrast volume for dynamic CT angiography in renal transplant patients using a multiphase CT protocol

  • 1. Department of Clinical Radiology, University Hospitals Grosshadern, Ludwig-Maximilians-University of Munich, Marchioninistr. 15, 81377 Munich (Germany)
  • 2. Department of Internal Medicine I, University Hospitals Grosshadern, University of Munich (Germany)

Description

Objectives: To study the feasibility of an optimized multiphase renal-CT-angiography (MP-CTA) protocol in patients with history of renal transplantation compared with Doppler-ultrasound (DUS). Methods: 36 Patients underwent both DUS and time-resolved, MP-CTA (12 phases), with a mean contrast-volume of 34.4 ± 5.1 ml. Quality of MP-CTA was assessed quantitatively (vascular attenuation) and qualitatively (grades 1–4, 1 = best). For the assessment of clinical value of MP-CTA, cases were grouped into normal, macrovascular (arterial/venous) and microvascular complications (parenchymal perfusion defect). DUS served as the standard of reference. Results: Using the best of 12 phases in each patient, optimal attenuation was 353 ± 111 HU, 337 ± 98 HU and 164 ± 51 HU in the iliac arteries, renal arteries, and renal veins, respectively. Mean image quality was 1.1 ± 0.3 (n = 36) and 2.1 ± 0.6 (n = 30) for the transplant renal arteries and veins, respectively. Six renal veins were non-diagnostic in MP-CTA. In 36 patients, MP-CTA showed 13 vascular complications and 10 parenchymal perfusion defects. DUS was not assessable in eight patients. Overall, MP-CTA showed 15 cases with pathology (42%) not identifiable with DUS. The mean effective radiation dose of the MP-CTA protocol was 13.5 ± 5.2 mSv. Conclusion: MP-CTA can be sufficiently performed with reduced contrast volume at reasonable radiation dose in renal transplant patients, providing substantially higher diagnostic yield than DUS.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.ejrad.2010.10.010

Additional details

Identifiers

DOI
10.1016/j.ejrad.2010.10.010;
PII
S0720-048X(10)00521-8;

Publishing Information

Journal Title
European Journal of Radiology
Journal Volume
80
Journal Issue
3
Journal Page Range
p. 692-698
ISSN
0720-048X
CODEN
EJRADR

INIS

Country of Publication
Netherlands
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
43078269
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
ARTERIES; BIOMEDICAL RADIOGRAPHY; KIDNEYS; PATIENTS; RADIATION DOSES; STANDARDS; TRANSPLANTS; VEINS
Descriptors DEC
BLOOD VESSELS; BODY; CARDIOVASCULAR SYSTEM; DIAGNOSTIC TECHNIQUES; DOSES; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIOLOGY

Optional Information

Copyright
Copyright (c) 2010 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.