Published February 2014 | Version v1
Journal article

Installation and commissioning of the new Fermi National Accelerator Laboratory H- Magnetron

  • 1. Proton Source Department, Fermi National Accelerator Laboratory, Batavia, Illinois 60510 (United States)

Description

The Fermi National Accelerator Laboratory (FNAL) 40 year old Cockcroft-Walton 750 keV injectors with slit aperture magnetron ion sources have been replaced with a circular aperture magnetron, Low Energy Beam Transport, Radio Frequency Quadrupole Accelerator, and Medium Energy Beam Transport, as part of the FNAL Proton Improvement Plan. The injector design is based on a similar system at Brookhaven National Laboratory. The installation, commissioning efforts, and source operations to date will be covered in this paper along with plans for additional changes to the original design to improve reliability by reducing extractor spark rates and arc current duty factor

Additional details

Identifiers

Publishing Information

Journal Title
Review of Scientific Instruments
Journal Volume
85
Journal Issue
2
Journal Page Range
vp.
ISSN
0034-6748
CODEN
RSINAK

Conference

Title
14. international conference on ion sources
Acronym
ICIS 2011
Dates
12-16 Sep 2011
Place
Giardini-Naxos, Sicily (Italy)

INIS

Country of Publication
United States
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
45074472
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
APERTURES; BEAM TRANSPORT; BNL; COMMISSIONING; DESIGN; FERMILAB ACCELERATOR; INSTALLATION; ION SOURCES; MAGNETRONS; RADIOWAVE RADIATION; RELIABILITY
Descriptors DEC
ACCELERATORS; CYCLIC ACCELERATORS; ELECTROMAGNETIC RADIATION; ELECTRON TUBES; ELECTRONIC EQUIPMENT; EQUIPMENT; MICROWAVE EQUIPMENT; MICROWAVE TUBES; NATIONAL ORGANIZATIONS; OPENINGS; RADIATIONS; SYNCHROTRONS; US AEC; US DOE; US ERDA; US ORGANIZATIONS

Optional Information

Notes
(c) 2013 AIP Publishing LLC