Published October 2014 | Version v1
Journal article

Effect of circularity of perforation holes in V-shaped blockages on heat transfer and friction characteristics of rectangular solar air heater duct

  • 1. Alternate Hydro Energy Centre, Indian Institute of Technology Roorkee, Roorkee, Uttrakhand 247667 (India)
  • 2. Mechanical and Industrial Engineering Department, Indian Institute of Technology Roorkee, Roorkee, Uttrakhand 247667 (India)

Description

Highlights: • Effect of perforation shapes of blocks on heat transfer has been investigated. • A new parameter, circularity which represents perforation shape is proposed. • Effect of angle of attack of V-blocks on heat transfer has been investigated. • Nusselt number and friction factor correlations have been developed. - Abstract: The effect of non-circular perforation holes in term of circularity of V-shaped blockages attached to one heated wall of a rectangular duct of solar air heater. Five different hole shapes ranging from circular to square to rectangular in the circularity range of 1–0.6 have been used with varying relative pitch of 4–12, relative blockage height of 0.4–1.0, open area ratio of 5–25% and angle of attack of 30–75° and Reynolds number of flow was varied between 2000 and 20,000. It has been found that there exists an optimum non-circular shape of perforation holes that yields maximum value of Nusselt number; a perfectly circular hole performs substantially inferior as compared to a non-circular hole of considerable non-circularity (ψ = 0.69). An improvement of Nusselt number value in the ratio of 1.13 has been found when circular perforation holes are replaced by rectangular holes of circularity of 0.69. Correlations of Nusselt number as well of friction factor are established in term of Reynolds number and geometrical parameters of blockages which can be used to predict the values of Nusselt number and friction factor with considerably good accuracy

Availability note (English)

Available from http://dx.doi.org/10.1016/j.enconman.2014.06.050

Additional details

Identifiers

DOI
10.1016/j.enconman.2014.06.050;
PII
S0196-8904(14)00575-5;

Publishing Information

Journal Title
Energy Conversion and Management
Journal Volume
86
Journal Page Range
p. 952-963
ISSN
0196-8904
CODEN
ECMADL

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
46103246
Subject category
S42: ENGINEERING;
Descriptors DEI
ACCURACY; DUCTS; FRICTION FACTOR; HEAT TRANSFER; HOLES; NUSSELT NUMBER; PERFORATION; REYNOLDS NUMBER; SHAPE; SOLAR AIR HEATERS
Descriptors DEC
AIR HEATERS; DIMENSIONLESS NUMBERS; ENERGY TRANSFER; EQUIPMENT; HEATERS; SOLAR COLLECTORS; SOLAR EQUIPMENT

Optional Information

Copyright
Copyright (c) 2014 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.