Published December 2016 | Version v1
Journal article

The effect of background signal and its representation in deconvolution of EPR spectra on accuracy of EPR dosimetry in bone

  • 1. Department of Physics and Biophysics, Medical University of Gdansk, Debinki 1, 80-211 Gdansk (Poland)
  • 2. Department of Oncology and Radiotherapy, Medical University of Gdansk, Debinki 7, 80-211 Gdansk (Poland)

Description

This study is about the accuracy of EPR dosimetry in bones based on deconvolution of the experimental spectra into the background (BG) and the radiation-induced signal (RIS) components. The model RIS's were represented by EPR spectra from irradiated enamel or bone powder; the model BG signals by EPR spectra of unirradiated bone samples or by simulated spectra. Samples of compact and trabecular bones were irradiated in the 30-270 Gy range and the intensities of their RIS's were calculated using various combinations of those benchmark spectra. The relationships between the dose and the RIS were linear (R2 > 0.995), with practically no difference between results obtained when using signals from irradiated enamel or bone as the model RIS. Use of different experimental spectra for the model BG resulted in variations in intercepts of the dose-RIS calibration lines, leading to systematic errors in reconstructed doses, in particular for high- BG samples of trabecular bone. These errors were reduced when simulated spectra instead of the experimental ones were used as the benchmark BG signal in the applied deconvolution procedures. (authors)

Availability note (English)

Available from doi: http://dx.doi.org/10.1093/rpd/ncw171

Additional details

Identifiers

Publishing Information

Journal Title
Radiation Protection Dosimetry
Journal Volume
172
Journal Issue
1-3
Journal Page Range
p. 275-282
ISSN
0144-8420

Conference

Title
4. EPR BioDose Meeting
Dates
4-8 Oct 2015
Place
Hanover, NH (United States)

INIS

Country of Publication
United Kingdom
Country of Input or Organization
France
INIS RN
48020008
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY; S62: RADIOLOGY AND NUCLEAR MEDICINE;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ACCURACY; BENCHMARKS; CALIBRATION; DOSIMETRY; ELECTRON SPIN RESONANCE; ENAMELS; ERRORS; IRRADIATION; RADIATION DOSES; SIMULATION; SKELETON; SPECTRA; TRABECULAR BONE
Descriptors DEC
ANIMAL TISSUES; BODY; BONE TISSUES; COATINGS; CONNECTIVE TISSUE; DOSES; MAGNETIC RESONANCE; ORGANS; RESONANCE

Optional Information

Notes
19 refs.