Published September 1999 | Version v1
Journal article

An EGS4-ready tomographic computational model of a 14-year-old female torso for calculating organ doses from CT examinations

  • 1. School of Nursing, Sturt Building, Flinders University, Adelaide, GPO Box 2100 Adelaide, South Australia, 5001 (Australia)
  • 2. AU
  • 3. Division of Medical Imaging, Women's and Children's Hospital, North Adelaide, South Australia, 5006 (AU)
  • 4. School of Physics and Electronic Systems Engineering, University of South Australia, The Levels Campus, Mawson Lakes, South Australia, 5095 (AU)

Description

Fifty-four consecutive CT scans have been used to construct a tomographic computational model of a 14-year-old female torso suitable for the determination of organ doses from CT. The model, known as ADELAIDE, is in the form of an input file compatible with user codes based on XYZDOS.MOR from the readily available EGS4 Monte Carlo radiation transport code. ADELAIDE's dimensions are close to the Australian averages for her age so the model is representative of a 14-year-old girl. The realistic anatomy in the model differs considerably from that in Cristy's 15-year-old mathematical computational model by having realistically shaped organs that are appropriately located within a real external contour. Average absorbed dose to organs from simulated CT examinations of the chest and abdomen have been calculated for ADELAIDE using EGS4 within a geometry specific to the General Electric Hi-Speed Advantage CT scanner and using an x-ray spectrum calculated using data from the scanner's x-ray tube. The simulations include the scanner's beam shaping filter and patient table. It is suggested that the resulting values have fewer possible sources of uncertainty than organ doses derived from dose coefficients calculated for a MIRD style model with mathematical anatomy and a spectrum that may not match that of the scanner. The organ doses were normalized using the scanner's CTDI measured free-in-air and an EGS4 simulation of the CTDI measurement. Effective dose to the torso from 26-slice chest and 24-slice abdomen examinations (at 120 kV, 200 mAs, 7 mm slices) is 4.6±0.1mSv and 4.3±0.1mSv respectively. (author)

Additional details

Publishing Information

Journal Title
Physics in Medicine and Biology (Online)
Journal Volume
44
Journal Issue
9
Journal Page Range
p. 2213-2225
ISSN
1361-6560

INIS

Country of Publication
International Atomic Energy Agency (IAEA)
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
31025406
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE; S61: RADIATION PROTECTION AND DOSIMETRY;
Descriptors DEI
ABDOMEN; CHEST; COMPUTERIZED TOMOGRAPHY; MATHEMATICAL MODELS; ORGANS; RADIATION DOSES; RADIATION TRANSPORT
Descriptors DEC
BODY; TOMOGRAPHY

Optional Information

Notes
Refs