Published June 1995 | Version v1
Journal article

Evaluation of compression radiotherapy in pelvic treatment

  • 1. International Medical Center, Tokyo (Japan)

Description

In pelvic irradiation, the volume of irradiated small intestine is one of the major factors responsible for both acute and late gastrointestinal complications. In this study, exclusion of the small intestine from the pelvic radiation field was attempted with lower abdominal wall compression and bladder distention in the prone position. The mobility of intrapelvic and several problems associated with this technique were investigated. In our results, the small intestine was effectively moved outside of the whole pelvic radiation field in all but two patients. Treatment interruption of 2 days was observed in only two patients. With the AP/PA opposing field method the abdominal skin dose near the compression pillow was revealed to be higher and the dose at the isocenter was inhomogeneous; thus, a three- or four-field technique is recommended if abdominal wall compression is used. (author)

Additional details

Publishing Information

Journal Title
Nippon Igaku Hoshasen Gakkai Zasshi
Journal Volume
55
Journal Issue
7
Journal Page Range
p. 501-504.
ISSN
0048-0428
CODEN
NHGZAR