Published June 1995
| Version v1
Report
Open
Magnetic fields and scintillator performance
Creators
- 1. Fermi National Accelerator Lab., Batavia, IL (United States)
- 2. Florida State Univ., Tallahasse, FL (United States)
Description
Experimental data have shown that the light output of a scintillator depends on the magnitude of the externally applied magnetic fields, and that this variation can affect the calorimeter calibration and possibly resolution. The goal of the measurements presented here is to study the light yield of scintillators in high magnetic fields in conditions that are similar to those anticipated for the LHC CMS detector. Two independent measurements were performed, the first at Fermilab and the second at the National High Magnetic Field Laboratory at Florida State University
Availability note (English)
MF available from INIS under the Report Number; Also available from OSTI as DE95014659; NTIS; US Govt. Printing Office Dep.Files
27001862.pdf
Files
(1.2 MB)
| Name | Size | Download all |
|---|---|---|
|
md5:30f6da350842b93c1e059315b4f45968
|
1.2 MB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 17 p.
- Report number
- FNAL-TM--1937
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 27001862
- Subject category
- S43: PARTICLE ACCELERATORS; S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- CALIBRATION; MAGNETIC FIELDS; MEASURING METHODS; PERFORMANCE; PLASTIC SCINTILLATORS; SHOWER COUNTERS
- Descriptors DEC
- MEASURING INSTRUMENTS; PHOSPHORS; RADIATION DETECTORS
Optional Information
- Contract/Grant/Project number
- Contract AC02-76CH03000
- Funding organization
- USDOE, Washington, DC (United States).