Flexible heliac configuration
Description
The addition of an l = 1 helical winding to the heliac central conductor adds a significant degree of flexibility to the configuration by making it possible to control the rotational transform and shear. Such control is essential for an experiment because the presence of low-order resonances in the rotational transform profile can cause breakup of the equilibrium magnetic surfaces. The use of the additional winding also permits reduction of the total central conductor current and can deepen the magnetic well
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS, PC A02/MF A01 as DE85009671.Files
16076151.pdf
Files
(485.6 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:519724ab3c5ffa10cd06399054cc42f8
|
485.6 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 23 p.
- Report number
- ORNL/TM--9504
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 16076151
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Descriptors DEI
- EQUILIBRIUM; HELICAL CONFIGURATION; MAGNET COILS; MAGNETIC SURFACES; ROTATIONAL TRANSFORM; SHEAR; STELLARATORS
- Descriptors DEC
- CLOSED PLASMA DEVICES; CONFIGURATION; ELECTRIC COILS; ELECTRICAL EQUIPMENT; EQUIPMENT; MAGNETIC FIELD CONFIGURATIONS; THERMONUCLEAR DEVICES