Published June 2018 | Version v1
Journal article

Radiation shielding design for treatment room of HIMM

  • 1. Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou (China)
  • 2. University of Chinese Academy of Sciences, Beijing (China)

Description

To guarantee the radiation safety of heavy ion medical machine (HIMM) during operation, the prompt neutron source term was calculated with the FLUKA code, and the effects of secondary neutron and gamma radiation on shielding were analyzed. The semiempirical formula and FLUKA code were adopted to calculate the shielding thickness, and the shielding design of HIMM treatment room was given. At the condition of full power operation of HIMM, the measured neutron dose rate is in agreement with the simulation result. The results indicate that the calculation method is reasonable, and the result is in accordance with the requirements of the national standard. (authors)

Additional details

Publishing Information

Journal Title
Atomic Energy Science and Technology
Journal Volume
52
Journal Issue
6
Journal Page Range
p. 1118-1123
ISSN
1000-6931

Optional Information

Notes
6 figs., 3 tabs., 10 refs.; http://dx.doi.org/10.7538/yzk.2017.youxian.0352