Published February 1999 | Version v1
Journal article

Measurement of plasma ion temperature and rotation velocity

  • 1. Guangzhou Normal Univ. (China). Dept. of Physics
  • 2. Academia Sinica, Hefei (China). Inst. of Plasma Physics

Description

The CV(at 227.1 nm) line has been measured with Optical Spectroscope Multichannel Analysis. The local ion temperature and rotation velocity has been derived using a chosen-point fitting technique

Additional details

Publishing Information

Journal Title
High Power Laser and Particle Beams
Journal Volume
11
Journal Issue
1
Journal Page Range
p. 93-96
ISSN
1001-4322