Published November 17, 1997 | Version v1
Report Open

Evaluation of selected ex-reactor accidents related to the tritium and medical isotope production missions at the Fast Flux Test Facility

Description

The Fast Flux Test Facility (FFTF) has been proposed as a production facility for tritium and medical isotopes. A range of postulated accidents related to ex-reactor irradiated fuel and target handling were identified and evaluated using new source terms for the higher fuel enrichment and for the tritium and medical isotope targets. In addition, two in-containment sodium spill accidents were re-evaluated to estimate effects of increased fuel enrichment and the presence of the Rapid Retrieval System. Radiological and toxicological consequences of the analyzed accidents were found to be well within applicable risk guidelines

Availability note (English)

Available from INIS in electronic form; ALSO AVAILABLE FROM OSTI AS DE99050349; NTIS; US GOVT. PRINTING OFFICE DEP.

Files

30060176.pdf

Files (4.4 MB)

Name Size Download all
md5:74c17ca9c5f806a360656fe9b56b8c4a
4.4 MB Preview Download

Additional details

Publishing Information

Imprint Pagination
551 p.
Report number
HNF-SD-FF-CN--013