Published 1983 | Version v1
Report Open

The wire, pad and direct cathode readout of streamer tubes

Description

Various methods of analogue data readont from streamer chambers being a part of the hadron calorimeter are compared. The data characterizing the distributions of the charge collected on tha anode wire are obtained. It is shown that for the direct cathode readont the value of crosstalks is less then 10% of the electrode maximum signal

Availability note (English)

MF available from INIS under the Report Number.

Files

16007151.pdf

Files (395.5 kB)

Name Size Download all
md5:3fab66c97da2c5e761f1edaf15215c9d
395.5 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
19 p.
Report number
ITEP--151(1983)

Optional Information

Notes
2 refs.; 13 figs.; 1 tab.