Specific kerma equivalent for photons and neutrons up to 20 MeV

  • 1. Gosudarstvennyj Komitet po Ispol'zovaniyu Atomnoj Ehnergii SSSR, Serpukhov. Inst. Fiziki Vysokikh Ehnergij
  • 2. Institut Biofiziki, Moscow (USSR)

Description

Specific kerma equivalent, specific Kerma and quality factor have been calculated for photons and neutrons in the photon energy range from 0.1 KeV to 20 MeV and the neutron energy range from thermal neutron energies up to 20 MeV. The latest recomendation of the tissue composition, the LET data for charged particles and more recent cross-sections data for photon and neutron reactions induced in tissue have been used. This information can be used to estimate the radiation dose equivalent and for the interpretation of the tissue-equivalent equidosemeter energy responses

Availability note (English)

MF available from INIS under the Report Number.

Files

18073325.pdf

Files (480.6 kB)

Name Size Download all
md5:39e72e79372ba4eb036a52b0962b5cc5
480.6 kB Preview Download

System files (46.2 kB)

Name Size Download all

Additional details

Additional titles

Original title (Russian)
Удельная ехвивалентная керма фотонов и нейтронов с энергией до 20 MehV

Publishing Information

Imprint Pagination
20 p.
Report number
IFVE-ORI--85-5

Optional Information

Notes
20 refs.; 7 figs.; 1 tab.