Published February 1, 2007 | Version v1
Journal article

A simple method to estimate coordinate resolution and MTF for pixelized detectors

  • 1. Instituto de Fisica UNAM, A.P. 20-364, 01000 DF (Mexico)

Description

A simple method to estimate the coordinate resolution of pixelized detectors, using non-single photon counting readout is proposed. This method can be useful particularly for testing detectors used in digital imaging systems. The proposal is based on the determination of the statistical correlation between detector neighbor pixels, by means of the statistical noise measurement of isolated pixels, and the linear combination of neighbor pixels. Distributions of differences between neighbor pixels are constructed for pixels sharing an edge or only having one common vertex. The method is validated using images from a GE Senographe 2000D mammographic unit. The pixelized detector has been irradiated by X-rays along its entire surface. The correlation asymmetry between perpendicular directions has been studied to estimate the possible existence of a hardware asymmetry. The coordinate resolution of the studied detector, pixel size 100 μm, is of the order of 50-55 μm, that is, almost twice as large as the value determined by geometry. A small asymmetry between the mutually perpendicular X and Y directions has been detected. The modulation transfer function (MTF) can be estimated from the correlation data, and the reconstructed MTF is in good agreement with measurements

Additional details

Identifiers

DOI
10.1016/j.nima.2006.10.128;
PII
S0168-9002(06)01926-7;

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
571
Journal Issue
1-2
Journal Page Range
p. 433-436
ISSN
0168-9002
CODEN
NIMAER

Conference

Title
1. international conference on molecular imaging technology
Acronym
EuroMedIm 2006
Dates
9-12 May 2006
Place
Marseille (France)

INIS

Country of Publication
Netherlands
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
38104391
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ASYMMETRY; COORDINATES; CORRELATIONS; DISTRIBUTION; IMAGES; IRRADIATION; MODULATION; NOISE; RADIATION DETECTORS; SPATIAL RESOLUTION; TESTING; X RADIATION
Descriptors DEC
ELECTROMAGNETIC RADIATION; IONIZING RADIATIONS; MEASURING INSTRUMENTS; RADIATIONS; RESOLUTION