Development of rapid urine analysis method for uranium

  • 1. Japan Atomic Energy Research Institute, Tokai, Ibaraki (Japan)

Description

ICP-MS has begun to spread in the field of individual monitoring for internal exposure as a very effective machine for uranium analysis. Although the ICP-MS has very high sensitivity, it requires longer time than conventional analysis, such as fluorescence analysis, because it is necessary to remove matrix from a urine sample sufficiently. To shorten time required for the urine bioassay by ICP-MS, a rapid uranium analysis method using the ICP-MS connected with a flow injection system was developed. Since this method does not involve chemical separation steps, the time required is equivalent to the conventional analysis. A measurement test was carried out using 10 urine solutions prepared from a urine sample. Required volume of urine solution is 5 ml. Main chemical treatment is only the digestion with 5 ml of nitric acid using a microwave oven to decompose organic matter and to dissolve suspended or precipitated matter. The microwave oven can digest 10 samples at once within an hour. Volume of digested sample solution was adjusted to 10 ml. The prepared sample solutions were directly introduced to the ICP-MS without any chemical separation procedure. The ICP-MS was connected with a flow injection system and an auto sampler. The flow injection system can minimize the matrix effects caused from salt dissolved in high matrix solution, such as non chemical separated urine sample, because it can introduce micro volume of sample solution into the ICP-MS. The ICP-MS detected uranium within 2 min/sample using the auto sampler. The 10 solutions prepared from a urine sample showed an average of 7.5 ng/l of uranium concentration in urine with 10 % standard deviation. A detection limit is about 1 ng/l. The total time required was less than 4 hours for 10 sample analysis. In the series of measurement, any memory effect was not observed. The present analysis method using the ICP-MS equipped with the flow injection system demonstrated that the shortening of time required on high sensitive uranium bioassay was successfully achieved without decline of sensitivity. (author)

Part of:
IRPA-10. Proceedings of the 10th international congress of the International Radiation Protection Association on harmonization of radiation, human life and the ecosystem

Additional details

Publishing Information

Publisher
Japan Health Physics Society
Imprint Place
Tokyo (Japan)
Imprint Title
IRPA-10. Proceedings of the 10th international congress of the International Radiation Protection Association on harmonization of radiation, human life and the ecosystem
Imprint Pagination
1 v.
Journal Page Range
[4 p.]

Conference

Title
10. international congress of the International Radiation Protection Association
Acronym
IRPA-10
Dates
14-19 May 2000
Place
Hiroshima (Japan)

Optional Information

Notes
This CD-ROM can be used for WINDOWS 95/98/NT, MACINTOSH; Acrobat Reader is included; Data in PDF format, No. P-3a-156; 5 refs., 3 tabs., 5 figs.