Published 2016 | Version v1
Journal article

A fast high-voltage current-peak detection system for the ALICE transition radiation detector

  • 1. Physikalisches Institut, Ruprecht-Karls-Universitaet Heidelberg (Germany)

Description

During LHC operation in run 1, the gaseous detectors of ALICE occasionally experienced simultaneous trips in their high voltage which affected the majority of the high voltage channels. These trips are caused by large anode currents in the detector and are potentially related to LHC machine operations. We developed and installed a fast current-peak detection system for the ALICE Transition Radiation Detector. This system is based on FPGA technology and monitors 144 out 522 high voltage channels minimally invasively at a maximum readout rate of 2 MHz. It is an integral part of the LHC beam monitoring system. We report on the latest status.

Additional details

Publishing Information

Journal Title
Verhandlungen der Deutschen Physikalischen Gesellschaft
Journal Issue
Darmstadt 2016 issue
Series
Also available as printed version: Verhandlungen der Deutschen Physikalischen Gesellschaft v. 51(4)
Journal Page Range
[1 p.]
ISSN
0420-0195
CODEN
VDPEAZ

Conference

Title
DPG-Fruehjahrstagung 2016 (Spring meeting) with the division hadron and nuclei, and the working group accelerator physics
Original Conference Title
DPG-Fruehjahrstagung 2016 des Fachverbandes Hadronen und Kerne und dem Arbeitskreis Beschleunigerphysik
Dates
14-18 Mar 2016
Place
Darmstadt (Germany)

Optional Information

Notes
Session: HK 44.4 Mi 17:30; No further information available
Collaborations
ALICE-Collaboration