Inhomogeneities in high energy photon beams used in radiotherapy. Experimental and theoretical studies

Description

This work is dedicated to the influence of the human body inhomogeneities on the dose distribution for high energy photons beams used in Radiotherapy. It consists in an experimental part and a theoretical analysis leading to original models of calculation. We study essentially, - the beam quality of the machines used and its influence on some basic dosimetric quantities and on the response of an ionization chamber. - The dose perturbation due to off-axis heterogeneous volumes at off-axis points of measurement; a model is suggested to take into account the perturbation of the multiple scatter. The perturbation of the dose in the transition region, between water equivalent medium and heterogeneous medium (air) is also investigated. The last part is devoted to computer applications of the proposed correction methods and to a comparison between the different computerized treatment planning systems which take into account of inhomogeneities

Availability note (English)

MF available from INIS under the Report Number.

Abstract (French)

Ce travail est consacre a l'etude de l'influence des heterogeneites du corps humain sur la distribution de la dose en Radiotherapie par photons de haute energie. Il comporte une partie experimentale et une analyse theorique debouchant sur la mise au point de modeles de calcul originaux. On y etudie notamment, - la qualite des faisceaux des appareils utilises et son influence sur les grandeurs dosimetriques fondamentales; les perturbations liees a la paroi de la chambre d'ionisation, - la perturbation de la dose due a des volumes heterogenes excentres et des points de mesure excentres aussi; le probleme de la prise en compte du diffuse multiple dans le calcul de la dose diffusee totale en presence des heterogeneites, - la dose dans la zone de transition pres des interfaces milieu equivalent-eau/milieu heterogene (air). Enfin, la derniere partie est consacree a l'adaptation informatique des methodes de correction proposees et a la comparaison de differents systemes informatiques de calcul de dose qui tiennent compte de la presence des heterogeneites

Files

17082812.pdf

Files (4.9 MB)

Name Size Download all
md5:cfc23a4a5c0b39b6eec9b73d7afa061c
4.9 MB Preview Download

Additional details

Additional titles

Original title (French)
Les heterogeneites dans les faisceaux de photons de haute energie employes en radiotherapie. Recherches experimentales et theoriques

Publishing Information

Imprint Pagination
259 p.
Report number
FRNC-TH--2283