Published June 2015 | Version v1
Journal article

Chemical effect evaluation of containment sump filter of CPR1000 nuclear power plants

  • 1. China Nuclear Power Engineering Company, Shenzhen (China)

Description

The chemical effects for the recirculation sump filter blockage of CPR1000 Nuclear Power Plant (NPP) under Loss of Coolant Accident (LOCA) is studied. In chemical effects evaluation, simulation experimentation is adopted. The result indicates that the effect of chemical effect on the emergency recycle is slight in CPR1000 NPP. (authors)

Additional details

Publishing Information

Journal Title
Nuclear Power Engineering
Journal Volume
36
Journal Issue
3
Journal Page Range
p. 125-128
ISSN
0258-0926

Optional Information

Notes
4 figs., 1 ref.