Published 1975
| Version v1
Journal article
Automatic method of radiometric measurement of flow intensity
Description
An automatic method of the flow intensity measurement is presented. The method is based on the point injection of a tracer and on the measurement of radioactivity in the water sample taken out from a cross-section where complete mixing of the river flow is reached. Injection is done by means of an automatic injector. In the measuring profile, a water pump is installed. Water is pumped through container with centrally inserted detector connected to measuring set. Measurements carried out by this method proved its applicability and good correlation with the results of measurements by means of the current meter (differences of 6,2%). (Z.M.)
Additional details
Publishing Information
- Journal Title
- J. Hydrol. Sci.
- Journal Volume
- 2
- Journal Issue
- 3-4
- Series
- J. Hydrol. Sci.
- Journal Page Range
- 183-194
INIS
- Country of Publication
- Poland
- Country of Input or Organization
- Poland
- INIS RN
- 9365309
- Subject category
- S58: GEOSCIENCES;
- Descriptors DEI
- FLOW RATE; MIXING; RADIOISOTOPES; RIVERS; TRACER TECHNIQUES; WATER
- Descriptors DEC
- HYDROGEN COMPOUNDS; ISOTOPE APPLICATIONS; ISOTOPES; OXYGEN COMPOUNDS; SURFACE WATERS