Design of the interface between EPICS IOC and LabWindows/CVI
Creators
- 1. University of Science and Technology of China, Hefei (China)
Description
Three interface methods between EPICS IOC and LabWindowe/CVI are introduced:CallBack function, Dynamic Link Library, AxtiveX Control. For a centralized data acquisition and control virtual instrument platform based on VXI bus developed by LabWindows/CVI as an example, the remote control of EPICS to the front end instrument has been realized. (authors)
Additional details
Publishing Information
- Journal Title
- Nuclear Electronics and Detection Technology
- Journal Volume
- 29
- Journal Issue
- 1
- Journal Page Range
- p. 59-61, 171
- ISSN
- 0258-0934
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 42035545
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Descriptors DEI
- CONTROL SYSTEMS; DATA ACQUISITION; E CODES; EQUIPMENT INTERFACES; FASTBUS SYSTEM; ICF DEVICES; L CODES; PLASMA DIAGNOSTICS; REMOTE CONTROL
- Descriptors DEC
- COMPUTER CODES; CONTROL; THERMONUCLEAR DEVICES
Optional Information
- Notes
- 5 figs., 5 refs.