Published January 18, 2016 | Version v1
Journal article

Measurement Technique of Dose Rate Distribution of Ionization Sources with Unstable in Time Beam Parameters

  • 1. Senior Researcher, Tomsk Polytechnic University, Tomsk (Russian Federation)
  • 2. Engineer, Tomsk Polytechnic University, Tomsk (Russian Federation)
  • 3. Bachelor student, Tomsk Polytechnic University, Tomsk (Russian Federation)

Description

The article describes a new technique for the average values of radiation dose measurement for the unstable gamma-ray sources which are used in non-destructive testing. The method is based on usage of different types of compact accumulative dosimeters. Spatially distributed position sensitive dosimetry system based on compact sensitive elements was created. Size and spatial resolution of the system of the dosimetry system are chosen taking into account sources characteristics. The proposed method has been tested on the measurement of dose distribution of several sources of X-ray and gamma-radiation based on X-ray tubes, electronic accelerator betatrons and linear electron accelerators. (paper)

Availability note (English)

Available from http://dx.doi.org/10.1088/1742-6596/671/1/012057

Additional details

Publishing Information

Journal Title
Journal of Physics. Conference Series (Online)
Journal Volume
671
Journal Issue
1
Journal Page Range
[5 p.]
ISSN
1742-6596

Conference

Title
3. all-Russian scientific and practical conference on innovations in non-destructive testing
Acronym
SibTest 2015
Dates
27-31 Jul 2015
Place