Published September 1, 2017 | Version v1
Journal article

A new hydraulic regulation method on district heating system with distributed variable-speed pumps

Description

Highlights: • A hydraulic regulation method was presented for district heating with distributed variable speed pumps. • Information and automation technologies were utilized to support the proposed method. • A new hydraulic model was developed for distributed variable speed pumps. • A new optimization model was developed based on genetic algorithm. • Two scenarios of a multi-source looped system was illustrated to validate the method. - Abstract: Compared with the hydraulic configuration based on the conventional central circulating pump, a district heating system with distributed variable-speed-pumps configuration can often save 30–50% power consumption on circulating pumps with frequency inverters. However, the hydraulic regulations on distributed variable-speed-pumps configuration could be more complicated than ever while all distributed pumps need to be adjusted to their designated flow rates. Especially in a multi-source looped structure heating network where the distributed pumps have strongly coupled and severe non-linear hydraulic connections with each other, it would be rather difficult to maintain the hydraulic balance during the regulations. In this paper, with the help of the advanced automation and information technologies, a new hydraulic regulation method was proposed to achieve on-site hydraulic balance for the district heating systems with distributed variable-speed-pumps configuration. The proposed method was comprised of a new hydraulic model, which was developed to adapt the distributed variable-speed-pumps configuration, and a calibration model with genetic algorithm. By carrying out the proposed method step by step, the flow rates of all distributed pumps can be progressively adjusted to their designated values. A hypothetic district heating system with 2 heat sources and 10 substations was taken as a case study to illustrate the feasibility of the proposed method. Two scenarios were investigated respectively. In Scenario I, the flow rate of one substation varied according to its heat demand and the flow rates of other substations maintained their original values. And in Scenario II, the flow rates of all substations varied synchronously with the same relative rate. The results of the both scenarios indicated that all pumps could be properly adjusted to their designated flow rates by the proposed method with a high frequency adjustment resolution as 0.001 Hz. In scenario I, compared with the district heating system with distributed variable-speed-pumps configuration, the power consumption would be 26.6–66.8% less than that of the conventional central circulating pump configuration during the 4 rounds of regulations. In scenario II, the energy saving ratio of the district system with distributed variable-speed-pumps configuration would be 36.1–90.3% less than that of the conventional central circulating pump configuration during the 5 rounds of regulations.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.enconman.2017.03.059

Additional details

Identifiers

DOI
10.1016/j.enconman.2017.03.059;
PII
S0196-8904(17)30270-4;

Publishing Information

Journal Title
Energy Conversion and Management
Journal Volume
147
Journal Page Range
p. 174-189
ISSN
0196-8904
CODEN
ECMADL

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
49047864
Subject category
S42: ENGINEERING;
Descriptors DEI
CONFIGURATION; DISTRICT HEATING; FLOW RATE; GENETIC ALGORITHMS; HEAT SOURCES; HEATING SYSTEMS; HYDRAULICS; NONLINEAR PROBLEMS; PUMPS; REGULATIONS
Descriptors DEC
ALGORITHMS; ENERGY SYSTEMS; EQUIPMENT; FLUID MECHANICS; HEATING; LAWS; MATHEMATICAL LOGIC; MECHANICS