Published May 1986 | Version v1
Journal article

Disappearance of a detached vapor mass in subcooled water

  • 1. Gunma Univ., Kiryu (Japan). Faculty of Technology

Description

Experiments on pool transition boiling of water under atmospheric pressure on a heated surface 10 mm in diameter were conducted for subcooling 15 - 50 K. The mass flux of condensation of a detached coalescent vapor bubble was experimentally estimated by a mathematical model based on the mass transfer mechanism of condensation. As a result, it is clarified that the mass flux of condensation of the detached bubble was influenced by the initial growing velocity of a vapor bubble immediately following the detached bubble. The disappearance velocity of the detached bubble defined as a ratio of the bubble diameter at the departure to the time required until the disappearance, is in the range 0.2 to 2.0 m/sec. The disappearance velocity is proportional to the initial growing velocity of the bubble, to the square of the heat flux of the heated surface and to the cube of the wall superheat, separately. (author)

Additional details

Publishing Information

Journal Title
Nippon Kikai Gakkai Ronbunshu, B Hen
Journal Volume
52
Journal Issue
477
Series
Nippon Kikai Gakkai Ronbunshu, B Hen.
Journal Page Range
2222-2227
ISSN
0387-5016
CODEN
NKGBD