Hybrid voltage divider used for high voltage pulsed power measurement

  • 1. Key Laboratory of Power Electrical and Power Drives, Chinese Academy of Sciences, Beijing (China)
  • 2. Institute of Electrical Engineering, Chinese Academy of Sciences, Beijing (China)
  • 3. Graduate University of Chinese Academy of Sciences, Beijing (China)

Description

The principle and structure of a hybrid voltage divider are proposed and the calibration and experimental testing are carried out. The ideal response conditions of the divider are analyzed by using the simplified divider model, the attenuation characteristic of two-stage voltage dividing is discussed, and then an error control method is presented. Through load calibration, the pulsed voltage frequency response of the divider can be greater than 2.9 MHz with the largest pulse width of 40 μs, the attenuation ratio (or the attenuation coefficient) of 2. 60 kV/V and the measurement error of less than 5%. The divider has the merits of low cost, easy fabrication, and being capable of ns-to μs-level pulsed voltage measurement, and it can be applied to laboratory- scale pulsed power measurement. (authors)

Additional details

Publishing Information

Journal Title
High Power Laser and Particle Beams
Journal Volume
24
Journal Issue
3
Journal Page Range
p. 529-534
ISSN
1001-4322

INIS

Country of Publication
China
Country of Input or Organization
China
INIS RN
45093380
Subject category
S43: PARTICLE ACCELERATORS;
Descriptors DEI
ATTENUATION; CALIBRATION; CONTROL; ELECTRIC POTENTIAL; ERRORS; HYBRIDIZATION; MHZ RANGE 01-100; POWER; PULSES; TESTING
Descriptors DEC
FREQUENCY RANGE; MHZ RANGE

Optional Information

Notes
4 figs., 9 refs.