Published October 1975 | Version v1
Report Open

Investigation on the behaviour of Fe++ and Cu++ chemical dosimeter under process conditions, including the influence of solute concentration in the system

  • 1. Danish Atomic Energy Commission, Risoe. Research Establishment

Description

The reaction mechanism proposed for the Fe-Cu dosemeter in the literature has failed to explain why the yield of Fe+++ is not a linear function of dose and why there is a difference in the initial yield when the solution is oxygen saturated as opposed to oxygen depleted. In addition, an investigation of the dose-rate effect on G(Fe+++) in oxygenated and oxygen depleted solutions yields results which have not proved amenable to the introduction of new reaction mechanisms. Pulse radiolysis studies have also failed to provide insight into additional reaction mechanisms which would explain the various discrepancies in the radiological behavior of the Fe-Cu system. In the present work, the Fe-Cu system was studied under extreme conditions of solute concentration and dose-rate. The experiments were aimed at determining the influence of concentrations of O2, Fe++, Fe+++ and Cu++ on the yield of Fe+++ in the irradiated Fe++-Cu++ dosemeter solution. Rapid mixing techniques were employed and a model reaction scheme developed for computer calculations to test the understanding of the radiochemical reactions. Methods for suppressing the reactions Cu++O2→Cu+++O2- and HO2+Fe++→HO2-+Fe+++ and thus improving dosemeter performance in a gamma field were determined. However, the investigation demonstrated that the dosemeter cannot be used for high dose-rate dosimetry of pulsed electron beams

Availability note (English)

MF available from INIS under the Report Number.

Files

7245092.pdf

Files (1.4 MB)

Name Size Download all
md5:459668c57fb195d475c581802e3bf93f
1.4 MB Preview Download

Additional details

Additional titles

Subtitle (English)
Final report for the period of 1 July 1972 - 30 June 1975

Publishing Information

Imprint Pagination
vp.
Report number
IAEA-R--1173-F

INIS

Country of Publication
International Atomic Energy Agency (IAEA)
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
7245092
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Descriptors DEI
CHEMICAL DOSEMETERS; CHEMICAL REACTION KINETICS; COPPER IONS; DOSE RATES; IRON IONS; PERFORMANCE; RADIATION DOSES; RADIOCHEMISTRY; SOLUTIONS
Descriptors DEC
ATOMIC IONS; CHARGED PARTICLES; CHEMISTRY; DISPERSIONS; DOSEMETERS; HOMOGENEOUS MIXTURES; IONS; KINETICS; MEASURING INSTRUMENTS; MIXTURES; REACTION KINETICS