Published September 20, 1982 | Version v1
Journal article

High-precision muonic x-ray measurement of the rms charge radius of 12C with a crystal spectrometer

  • 1. Laboratorium fuer Hochenergiephysik der Eidgenoessische Techische Hochschule Zuerich, c/o SIN, CH-5234 Villigen, Switzerland

Description

A precision measurement with the SIN bent-crystal spectrometer of the wave length of the 2P/sub 3/2/-1S/sub 1/2/ transition in muonic 12C yields lambda = 16.473 766(89) pm; the accuracy being an order of magnitude higher than that of earlier investigations. The rms charge radius of 12C is deduced as /sup 1/2/ = 2.482 6(18) fm, differing by 2.3 standard deviations from the most accurate electron-scattering results. Consequences of attributing this discrepancy to a μ-N interaction beyond QED are discussed

Additional details

Publishing Information

Journal Title
Phys. Rev. Lett.
Journal Volume
49
Journal Issue
12
Series
Phys. Rev. Lett.
Journal Page Range
859-862
ISSN