Published September 2007 | Version v1
Journal article

Measurements of carbon dioxide and oxygen concentrations in a diffusion respirator on the basis of track membranes

  • 1. Joint Institute for Nuclear Research, Dubna (Russian Federation)

Description

Concentrations of CO2 and O2 in the breathing hose and inside the mask of the diffusion respirator have been measured using an atomic emission spectrometer. The gas exchange system of this respirator efficiently, within 1 min, restores oxygen concentration in the inhaled air from 18.5 vol % to its atmospheric concentration (21 vol %) and carbon dioxide concentration from 2.9 vol % to a stationary concentration of ∼0.12 vol %. In the optimal configuration of the respirator, CO2 concentration inside the mask during breath is 0.23 vol %. The time resolution of the method is 200 ms and the CO2 detection limit is 0.08 vol %.

Availability note (English)

Available from http://link.springer.com/openurl/pdf?id=doi:10.1134/S1547477107050093

Additional details

Publishing Information

Journal Title
Physics of Particles and Nuclei Letters (Print)
Journal Volume
4
Journal Issue
5
Journal Page Range
p. 432-439
ISSN
1547-4771

INIS

Country of Publication
Russian Federation
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
52051250
Subject category
S37: INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY; S60: APPLIED LIFE SCIENCES;
Descriptors DEI
ABUNDANCE; CARBON DIOXIDE; DIFFUSION; MEMBRANES; OXYGEN; RESPIRATORS; TIME RESOLUTION
Descriptors DEC
CARBON COMPOUNDS; CARBON OXIDES; CHALCOGENIDES; ELEMENTS; NONMETALS; OXIDES; OXYGEN COMPOUNDS; RESOLUTION; TIMING PROPERTIES

Optional Information

Copyright
Copyright (c) 2007 Pleiades Publishing, Ltd.