Published March 2006 | Version v1
Journal article

New approach to meaning of minimally sufficient emergency protection of VVEhR

  • 1. OKB Gidropress, Podol'sk (Russian Federation)

Description

A new approach is proposed to determining the minimum sufficient number of the reactor control system (RCS) elements and the efficiency of the WWER emergency protection. The approach includes a new probabilistic method for determining the emergency protection efficiency in the case of failures of different number of control elements. Taking as an example the WWER-1000 reactor it is shown that sufficiency of the efficiency of the emergency protection with 49 control elements of RCS for the design accident with steam line rupture

Abstract (Russian)

Предложен подход к определению минимально достаточного числа органов регулирования СУЗ и эффективности аварийной защиты ВВЭР. Он включает в себя новый вероятностный метод определения эффективности аварийной защиты при отказах различного числа органов регулирования. На примере ВВЭР-1000 показана достаточность эффективности аварийной защиты с 49 органами регулирования СУЗ для определяющей проектной аварии с разрывом паропровода

Additional details

Additional titles

Original title (Russian)
Новый подход к определению минимально достаточной эффективности аварийной защиты VVEhR
Augmented title (English)
design accident

Publishing Information

Journal Title
Atomnaya Ehnergiya
Journal Volume
100
Journal Issue
3
Journal Page Range
p. 184-197
ISSN
0004-7163
CODEN
AENGAB

Optional Information

Notes
10 refs., 5 figs., 2 tabs.