Published September 1996 | Version v1
Journal article

Factors affecting γ spectrum analysis for real-time fuel element rupture detection

  • 1. Medical Research Inst., Shanghai (China)

Description

The authors describe the factors affecting γ spectrum measurement and analysis of reactor fuel element rupture detection. The main interference factors are γ rays from 19O, 16N and corrosion, annihilation radiation by high energy γ rays and 75 keV X ray from Pb shield. Above results have been successfully applied to the monitoring and analyzing of element safety in reactor

Additional details

Publishing Information

Journal Title
Nuclear Electronics and Detection Technology
Journal Volume
16
Journal Issue
5
Journal Page Range
p. 345-349.
ISSN
0258-0934
CODEN
HDYUEC

INIS

Country of Publication
China
Country of Input or Organization
China
INIS RN
28018722
Subject category
S22: GENERAL STUDIES OF NUCLEAR REACTORS;
Descriptors DEI
FAILED ELEMENT DETECTION; FUEL ELEMENT FAILURE; GAMMA FUEL SCANNING; GAMMA SPECTROSCOPY; INTERFERENCE; REAL TIME SYSTEMS
Descriptors DEC
ACCIDENTS; DETECTION; FUEL SCANNING; REACTOR ACCIDENTS; SPECTROSCOPY