Fiber-optic detector for real time dosimetry of a micro-planar x-ray beam
Creators
- 1. Medical Physics Graduate Program, Duke University Medical Center, Durham, North Carolina 27705 and Duke Radiation Dosimetry Laboratory, Duke University Medical Center, Durham, North Carolina 27710 (United States)
- 2. Department of Chemistry, Duke University, 124 Science Drive, Durham, North Carolina 27708 (United States)
- 3. Department of Physics and Astronomy, University of North Carolina, Chapel Hill, North Carolina 27599 (United States)
- 4. Department of Physics and Astronomy, University of North Carolina, Chapel Hill, North Carolina 27599 and UNC Lineberger Comprehensive Cancer Center, Chapel Hill, North Carolina 27599 (United States)
- 5. UNC Lineberger Comprehensive Cancer Center, Chapel Hill, North Carolina 27599 (United States)
- 6. Department of Radiation Oncology, University of North Carolina, Chapel Hill, North Carolina 27599 (United States)
- 7. and Department of Radiology, Duke University Medical Center, Durham, North Carolina 27710 (United States)
- 8. Duke Radiation Dosimetry Laboratory, Duke University Medical Center, Durham, North Carolina 27710 (United States)
- 9. Medical Physics Graduate Program, Duke University Medical Center, Durham, North Carolina 27705 (United States)
Description
Purpose: Here, the authors describe a dosimetry measurement technique for microbeam radiation therapy using a nanoparticle-terminated fiber-optic dosimeter (nano-FOD). Methods: The nano-FOD was placed in the center of a 2 cm diameter mouse phantom to measure the deep tissue dose and lateral beam profile of a planar x-ray microbeam. Results: The continuous dose rate at the x-ray microbeam peak measured with the nano-FOD was 1.91 ± 0.06 cGy s−1, a value 2.7% higher than that determined via radiochromic film measurements (1.86 ± 0.15 cGy s−1). The nano-FOD-determined lateral beam full-width half max value of 420 μm exceeded that measured using radiochromic film (320 μm). Due to the 8° angle of the collimated microbeam and resulting volumetric effects within the scintillator, the profile measurements reported here are estimated to achieve a resolution of ∼0.1 mm; however, for a beam angle of 0°, the theoretical resolution would approach the thickness of the scintillator (∼0.01 mm). Conclusions: This work provides proof-of-concept data and demonstrates that the novel nano-FOD device can be used to perform real-time dosimetry in microbeam radiation therapy to measure the continuous dose rate at the x-ray microbeam peak as well as the lateral beam shape
Additional details
Identifiers
- DOI
- 10.1118/1.4915078;
Publishing Information
- Journal Title
- Medical Physics
- Journal Volume
- 42
- Journal Issue
- 4
- Journal Page Range
- p. 1966-1966.7
- ISSN
- 0094-2405
- CODEN
- MPHYA6
INIS
- Country of Publication
- United States
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 46119385
- Subject category
- S60: APPLIED LIFE SCIENCES;
- Descriptors DEI
- BEAM PROFILES; DOSEMETERS; DOSIMETRY; MICE; PHANTOMS; RADIATION DOSES; RADIOTHERAPY; X RADIATION
- Descriptors DEC
- ANIMALS; DOSES; ELECTROMAGNETIC RADIATION; IONIZING RADIATIONS; MAMMALS; MEASURING INSTRUMENTS; MEDICINE; MOCKUP; NUCLEAR MEDICINE; RADIATIONS; RADIOLOGY; RODENTS; STRUCTURAL MODELS; THERAPY; VERTEBRATES
Optional Information
- Notes
- (c) 2015 American Association of Physicists in Medicine