Published November 15, 2015 | Version v1
Journal article

Evaluation of optimal dual axis concentrated photovoltaic thermal system with active ventilation using Frog Leap algorithm

  • 1. Electrical Engineering Department, Amirkabir University of Technology (AUT), Tehran (Iran, Islamic Republic of)
  • 2. Electrical Engineering Department, Center of Energy, Power & Sustainability (EPS), Florida International University (FIU), Miami (United States)

Description

Highlights: • Electro-thermal performance of open-loop controlled dual axis CPVT is investigated. • For using the absorbed heat, active ventilation with a heat storage tank is used. • Economic optimization of the system is performed, using Frog Leap algorithm. • Detailed model of all sections is simulated with their characteristics evaluation. • Triple-junction photovoltaic cells, which are the most recent technology, are used. - Abstract: In this study, design and optimization of a concentrated photovoltaic thermal (CPVT) system considering electrical, mechanical, and economical aspects is investigated. For this purpose, each section of the system is simulated in MATLAB, in detail. Triple-junction photovoltaic cells, which are the most recent technology, are used in this study. They are more efficient in comparison to conventional photovoltaic cells. Unlike ordinary procedures, in this work active ventilation is used for absorbing the thermal power of radiation, using heat storage tanks, which not only results in increasing the electrical efficiency of the system through decreasing the temperature, but also leads to storing and managing produced thermal energy and increasing the total efficiency of the system up to 85 percent. The operation of the CPVT system is investigated for total hours of the year, considering the needed thermal load, meteorological conditions, and hourly radiation of Khuznin, a city in Qazvin province, Iran. Finally, the collector used for this system is optimized economically, using frog leap algorithm, which resulted in the cost of 13.4 $/m2 for a collector with the optimal distance between tubes of 6.34 cm.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.enconman.2015.08.033

Additional details

Identifiers

DOI
10.1016/j.enconman.2015.08.033;
PII
S0196-8904(15)00779-7;

Publishing Information

Journal Title
Energy Conversion and Management
Journal Volume
105
Journal Page Range
p. 782-790
ISSN
0196-8904
CODEN
ECMADL

Optional Information