Published October 2008 | Version v1
Journal article

Diagnostic developments for quasicontinuous operation of the Wendelstein 7-X stellarator

  • 1. Euratom Association, Max-Planck-Institut fuer Plasmaphysik, Wendelsteinstr. 1, 17491 Greifswald (Germany)
  • 2. Euratom Association, KFKI-Research Institute for Particle and Nuclear Physics, H-1121 Budapest, Konkoly Thege 29-33 (Hungary)
  • 3. Department of Applied Mechanics, Euratom Association, Budapest University of Technology and Economics, P.O. Box 91, H-1521 Budapest (Hungary)

Description

The stellarator Wendelstein 7-X will allow for quasicontinuous operation with the duration only being limited to two 30 min discharges per day, at a continuous heating power of 10 MW electron cyclotron resonance heating (ECRH) at 140 GHz, by the capacity of the cooling water reservoir. This will result in high thermal loads on all plasma facing components of 50-100 kW/m2 from radiation alone and of up to about 500 kW/m2 on components additionally exposed to convective loads. In high density scenarios toroidally varying ECRH stray radiation levels of 50-200 kW/m2 need to be coped with, requiring careful material selection and different shielding and hardening techniques. Furthermore, a gradual buildup of coatings on plasma facing optical components, which without any measures being taken, would lead to high transmission losses already within a few days of long pulse operation (equivalent to about 1 year of operation in pulsed devices like JET or ASDEX-upgrade) and therefore needs to be prevented as much as possible. In addition in situ cleaning as well as absolute calibration techniques need to be developed for all plasma facing optical systems. Here we report about some of our efforts to find, for various types of diagnostics, ways to cope with these adverse effects. Moreover, we give a few examples for individual diagnostic specific issues with respect to quasicontinuous operation, such as the development of a special integrator for the magnetic diagnostics as well as special interferometer types which can cope with unavoidable vibrations and slow path length changes due to, e.g., thermal expansion of the plasma vessel.

Additional details

Identifiers

Publishing Information

Journal Title
Review of Scientific Instruments
Journal Volume
79
Journal Issue
10
Journal Page Range
p. 10F337-10F337.4
ISSN
0034-6748
CODEN
RSINAK

Conference

Title
17. topical conference on high-temperature plasma diagnostics
Acronym
HTPD08
Dates
11-15 May 2008
Place
Albuquerque, NM (United States)

Optional Information

Notes
(c) 2008 American Institute of Physics