Published March 2015 | Version v1
Journal article

Analytical study on ultimate pressure capacity of prestressed concrete containment vessel

  • 1. Kansai Electric Power Co., Inc., Osaka (Japan)
  • 2. Mitsubishi Heavy Industries, Ltd., Tokyo (Japan)
  • 3. Obayashi Corp., Tokyo (Japan)

Description

Method of evaluating ultimate pressure capacity of Prestressed Concrete Containment Vessel (PCCV) in severe accident condition is currently being standardized to be published as a guideline by Main committee on Power Generation Facility Codes of the Japan Society of Mechanical Engineers. This paper reports the results of trial evaluations of the concrete and liner parts of the typical PCCV in accordance with the proposed guideline. (author)

Additional details

Publishing Information

Journal Title
Karyoku Genshiryoku Hatsuden
Journal Volume
66
Journal Issue
3
Journal Page Range
p. 181-187
ISSN
0387-1029

Optional Information

Notes
8 refs., 10 figs., 8 tabs.