Published July 1978 | Version v1
Journal article

Tc-99m human serum albumin: a suitable agent for plasma volume measurements in man

Description

In 16 patients we have carried out simultaneous plasma-volume measurements with human serum albumins tagged with Tc-99m (Tc-99m HSA) and I-131 (I-131 HSA). The correlation coefficient was 0.987. Tc-99m HSA, prepared from kits that predictably yield high labeling efficiency (and thereby negligible amounts of TcO4-), is clearly a superior agent for repeat plasma volume determinations, because of its shorter half-life and the reduced radiation dose to the subject

Additional details

Additional titles

Augmented title (English)
Comparision with "1"3"1I-HSA

Publishing Information

Journal Title
J. Nucl. Med.
Journal Volume
19
Journal Issue
7
Series
J. Nucl. Med.
Journal Page Range
804-807