Safety and feasibility in highly concentrated contrast material power injections for CT-perfusion studies of the brain using central venous catheters
Creators
- 1. University Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, D-40225 Dusseldorf (Germany)
- 2. University Dusseldorf, Medical Faculty, Department of Neurosurgery, D-40225 Dusseldorf (Germany)
- 3. University Dusseldorf, Medical Faculty, Department of Anaesthesiology, D-40225 Dusseldorf (Germany)
Description
Introduction: CT perfusion studies play an important role in the early detection as well as in therapy monitoring of vasospasm after subarachnoid hemorrhage. High-flow injections via central venous catheters are not recommended but may sometimes be the only possibility to obtain high-quality images. Materials and methods: We retrospectively analyzed our data for CT perfusions performed with power injection of contrast material with an iodine concentration of 400 mg/ml via the distal 16G lumen of the Arrow three and five lumen central venous catheter with preset flow rates of 5 ml/s. Results: 104 examinations with central venous catheters were evaluated (67 with five lumen and 37 with three lumen). No complications were observed. Mean flow rates were 4.4 ± 0.5 ml/s using the three lumen catheter and 4.6 ± 0.6 ml/s using the five lumen catheter respectively. The mean injection pressure measured by the power injector was 200.7 ± 17.5 psi for the three lumen central venous catheter and 194.5 ± 6.5 psi for the five lumen catheter, respectively. Conclusion: Following a strict safety protocol there were no complications associated with power injections of contrast material containing 400 mg iodine/ml with preset flow rates up to 5 ml/s via the distal 16G lumen of the Arrow multi-lumen central venous catheter. However, since power-injections are off-label use with Arrow central venous catheters, this procedure cannot be recommended until potential safety hazards have been ruled out by the manufacturer.
Availability note (English)
Available from http://dx.doi.org/10.1016/j.ejrad.2011.04.043Additional details
Identifiers
- DOI
- 10.1016/j.ejrad.2011.04.043;
- PII
- S0720-048X(11)00437-2;
Publishing Information
- Journal Title
- European Journal of Radiology
- Journal Volume
- 81
- Journal Issue
- 8
- Journal Page Range
- p. 1883-1885
- ISSN
- 0720-048X
- CODEN
- EJRADR
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 45027756
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BIOMEDICAL RADIOGRAPHY; BRAIN; COMPUTERIZED TOMOGRAPHY; CONCENTRATION RATIO; CONTRAST MEDIA; DIAGNOSIS; FLOW RATE; HAZARDS; HEMORRHAGE; IMAGE PROCESSING; IMAGES; INJECTION; IODINE; THERAPY
- Descriptors DEC
- BODY; CENTRAL NERVOUS SYSTEM; DIAGNOSTIC TECHNIQUES; DIMENSIONLESS NUMBERS; ELEMENTS; HALOGENS; INTAKE; MEDICINE; NERVOUS SYSTEM; NONMETALS; NUCLEAR MEDICINE; ORGANS; PATHOLOGICAL CHANGES; PROCESSING; RADIOLOGY; SYMPTOMS; TOMOGRAPHY
Optional Information
- Copyright
- Copyright (c) 2011 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.