Spontaneous migration of a portacath into the azygos vein with subsequent development of a tracheo-azygos fistula
Creators
- 1. Department of Radiology, Tauranga Hospital, Tauranga (New Zealand)
Description
Subcutaneous venous port or 'portacath' devices are widely used, especially in oncology patients. Several potential complications of portacath devices have been well documented. We report a rare case of the spontaneous migration of the tip of a portacath into the azygos vein, with subsequent development of a tracheo-azygos fistula. This resulted in the patient receiving a dose of chemotherapy agent and saline directly into his lungs, which ultimately contributed to his death a few weeks later. To our knowledge, there have been only 10 previously reported cases of inadvertent intrathoracic (mediastinal, pleural or pulmonary) extravasation of chemotherapy agent as a result of central venous catheter malposition or perforation; this is the second reported case of extravasation of chemotherapy agent as a result of migration of a portacath device into the azygos vein.
Availability note (English)
Available from http://dx.doi.org/10.1111/1754-9485.12210Additional details
Identifiers
Publishing Information
- Journal Title
- Journal of Medical Imaging and Radiation Oncology
- Journal Volume
- 59
- Journal Issue
- 2
- Journal Page Range
- p. 200-203
- ISSN
- 1754-9477
INIS
- Country of Publication
- Australia
- Country of Input or Organization
- Australia
- INIS RN
- 46062945
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ACCIDENTS; CHEMOTHERAPY; CRITICAL ORGANS; DAMAGE; DEATH; HAZARDS; INTRAVENOUS INJECTION; LUNGS; METASTASES; NEOPLASMS; RADIATION DOSES; VEINS
- Descriptors DEC
- BLOOD VESSELS; BODY; CARDIOVASCULAR SYSTEM; DISEASES; DOSES; INJECTION; INTAKE; MEDICINE; ORGANS; RESPIRATORY SYSTEM; THERAPY
Optional Information
- Notes
- 5 figs.